Sewer force main cleanout detail - Measurement Each sanitary sewer cleanout will be counted.

 
8 in. . Sewer force main cleanout detail

The following navigation utilizes arrow, enter, escape, and space bar key commands. S-13 MANHOLE BASE SECTION CAST IN PLACE. A private sewer lateral (PSL) is the pipe that connects the plumbing in a home or business to the sanitary sewer main, usually located in the street. MAINTENANCE VEHICLE ACCESS TO SEWER MANHOLES AND CLEANOUTS SHALL BE. s-10 residential force main s-11 sanitary sewer typical trench & bedding detail s-12 sanitary sewer location adjacent to water lines s-13 typical house lateral s-14 typical cleanout s-15 natural clay drainage stops road, sidewalk, & driveway details p-1a a pavement cut policy. sewer force main. Show items that are not contained in these Standards with detail . list of sewer details 1. Connection to Existing Manhole Comply with Section 6010, 1. North Charleston Sewer District 7225 Stall Road North Charleston, SC 29406. The Engineering & Design Standards provide specific direction and guidelines to design professionals preparing construction documents for private land development projects andor city CIP projects. to force main detail ccwsa. S15 - Polypropylene Manhole Step. 02 Pipe Bedding 15. 4 min. 00 Sewer Cleanout Pavement SEW-10A. Sanitary Sewer System. Sanitary Sewer Manhole Detail. The lines shall be laid in strict compliance with. wastewater main wye branch to match main pipe material. A four-inch diameter sewer pipe can withstand well over two tons of pressure per linear foot. STANDARD DETAILS. 105 SPECIAL UTILITY CROSSING. 13 Ductile Iron Pipe and Fittings. Product Details. 10 Typical Invert Plan A2. S-5 Terminal Cleanout Jan 2019 S-6 Sewer Trench Jan 2019 S-7 Steel Casing for Sewer Pipe Jan 2019. Standard Detail for Concrete Encasement, for a length as directed by the City Engineer. RECLAIMED WATER. details sewer mains. D&L SUPPLY E-1925 LOCK. Main to be abandoned shall not be valved off and shall not be cut or plugged other than as shown on Drawings. 40s force main air release valve and manhole in paved areas and road right-of way. FM-005 Typical Force Main Connection Detail (PDF) FM-006 Force Main Inside Drop Detail (PDF) FM-007 Forcemain Bedding Detail. JOINTS WITH STAINLESS STEEL BOLTS. 1999 standard number sd-301. new servicewater and sewer main extensionsdeveloper agreements. Policy No. Installation of 3 force main cleanout manholes; Installation of an air release valve. Dec 20, 2017 SAN-11 Building Sewer. TYPICAL ADJUSTABLE. Water and Wastewater Procedures and Design Manual - October 2015 (12. sewer dwg no. 6&177; ff134. SS-1 Sanitary Sewer Cleanout. Transition Manhole Force Main to Gravity Sewer. A blow-off is typically placed at the low points where gritty material could accumulate and restrict flow through the force main. Thompsons Station, TN Page 3 of 77 Issued 04132021. A blow-off is typically placed at the low points where gritty material could accumulate and restrict flow through the force main. S14 Roadway Sanitary Force Main Air & Vacuum Release Valve. Increasing Size S300-4 S309. The low pressure cleanout assembly shall be paid for at the contract bid price per each which shall include the cost of furnishing low pressure cleanout assembly device, piping, tees,. Created September 6, 2011 SAN-9-2 City Utilities Design Standards Manual. 1flexible manhole sleeve ss-7. Refer to example details Figures 1-9. (Sewer-Water Main) Crossing Details. s-42 force main or low pressure sewer connection to manhole. Roto-Rooter does more than unclog drains. 1130-1155 CIPP or Geopolymer How to. Location map. thickness sdr-21 pvc, gasketed. 0 Low Pressure Sewer System Main and Service Lateral Materials a) Low pressure sewer system mains shall be 1) PVC pipe manufactured in accordance with ASTM D1785, ASTM D2241,. Low Pressure Sewers 6. sewer line shall be encased in concrete where sewer water line crossings occur and where conditions prevent an 18" vertical separation. 18 Excavation. The wastewater is sanitized first before it is eventually released. If the force main will not drain, specify a burial depth in accordance with the. Sanitary Sewer Force Main (6126-6139) 6126 Connection to existing pressure main (PDF) 6127 Force main clean-out & tracer wire details (PDF) 6128 1" Air & Vacuum Release Valve for 10" & Smaller Low Pressure Sewer Mains (PDF) 6129 2" Air & Vacuum Release Valve for 12" & Larger Low Pressure Sewer Mains (PDF) 6130 Sanitary sewer cast iron valve box. GS-010 Cleanout Detail (PDF). 04 MB PDF). Areas of Expertise. SEWERFORCE MAIN. Sammamish Plateau Water and Sewer District. CLEANOUTS IN SIDEWALKS SHALL BE HOUSED IN METER BOX. Building Court Main Sewer The extension from the building court house sewer to a public sewer or other place of disposal. 513A 4" & 6" Sewer Service Lateral and Two Way Cleanout September 2017 515 Discharge for Private Force Main September 2017 517 Miscellaneous Pipe Installation Details September 2017 518 PVC Sewer Pipe Deflection Mandrel September 2017. This is the main reason that the sewer mains owned and maintained by the city are typically located between 10 and 15 deep. 10 Connections Utilizing an Existing Lateral 43. Plastic cleanout plugs shall conform to the requirements of Section 702. sewer force main cleanout manhole n. plastic marker shall be green in color. 5 sewer) plug valve throughout pipe support recommendations footer per manufacturers dip or pvc dip or pvc or approved for all pipes passing note to be used through walls. The beauty of. Created Date 12272012 105103 AM. Flexible Tap Saddles provide a soil-tight seal. Typical Cleanout. GS-010 Cleanout Detail (PDF) GS-011 Standard Manhole Frame and Cover (PDF) GS-012 Manhole Joint Detail. S-22 - House Service Connection Clean-out S-23 - Concrete Anchors S-24 - Lamphole S-25 - Sewage Combination Air Valve in Manhole S-26 - Pump Around S-27 - Precast Manhole Setting within 5 LF of Face of Curb S-28 - Sanitary Cleanout in Paving. 31 LPFM - FLUSHING CLEANOUT PIPE INTERSECTION. all pvc pipe shall be pressure rated Installed 140 of sewer main lines with new cleanouts, and risers & covers Since cleanouts aren't required frequently, your own may be covered by shrubs, underbrush or turf Valve boxes shall not be located in roadways or driveways Storm Sewer Manhole Type "B" - Non-Circular Walls Storm Sewer. Look for a small white pipe that sticks a few inches out of the ground. Manholes that receive discharge from force mains shall be coated with Epoxy Tech CPP series epoxy or approved equal. Pipe for sanitary sewer force mains shall conform to the requirements of AWWA C-900, Class 150, DR 18 pipe. Properly installed SDR35 solvent weld sewer fittings provide leak-proof joint. All cleanout structures installed in asphalt or concrete shall be. WHEN JOINING TWO PIECES OF MAIN OR LATERAL, USE A NEOPRENE RUBBER SLEEVE. To clean your main sewer line, locate your sewer cleanout and slowly remove the cap. 37 " Sanitary Gravity Sewer and " Force Main Sewer will be measured from end to end in 38 place with no deduction for length through manholes, valves or fittings and paid per linear 39 foot for the appropriate size. 12 Stream and Drainage . PROVIDE KNOCK OUTS. Cast-iron sewer pipe is heavy and difficult for a do-it-yourselfer to cut. east jordan 1310z frame, 1310a cover. Standard Sanitary Sewer Details - Pierce County, WA. ) Figure 5 Building Sewer Connection Figure 6 Precast Reinforced Concrete Manhole Figure 7 Cored Hole Flexible Pipe-to-M. sewer force main cleanout manhole n. reclaimed water shall be considered as potable water when placed city. min hyfe hyfe flange vent detail factory cast in place pipe flange 12" above mh top proposed grade vent opening to be 2&x27; min above 100 year flood elevation (opening to be screened) 4" hot dipped galv pipe standard typical vent tongue & grove joint with. If you have any questions about these drawings, please contact an NPU Project Coordinator at 860-823-4513. Sanitary Sewer Cleanout. wall pipe entire pipe equal around adeka seal seal detail wall concrete grout cement valve. NOTES 1. Force mains use pressure to pump out the wastewater to the treatment plants. Plastic cleanout plugs shall conform to the requirements of Section 702. sanitary sewer 4'-0" diameter precast 5' diameter & greater section a-a note precast sanitary sewer manhole detail manhole for force main discharge 6' diameter sanitary sewer corrosion resistant top detail top detail section a-a foundation plan 3200 durostreet&174; composite assembly a 14 turn locking cam 4x drill dimple a 32" 1 12" 32 116" 30. thickness sdr-21 pvc, gasketed. 9 MB PDF) Section 1 Manhole Structures Section 2 Laterals and Cleanouts Section 3 Pipe Trenching Section 4 Force Mains Section 5 Low Pressure Sewer Electrical Standard Details Electrical Standard Details Full Set (0. Weston & Sampson worked together with Spartanburg Sanitary Sewer District to design a 42" Force Main Pig Launch at Lawson&x27;s Fork Pump Station & Retrieval at Fairforest Wastewater Treatment Plant (WWTP). Existing Streets. - All sewer mains shall be located in public. The PSL carries sewage from a building to a public sanitary sewer. STANDARD DETAILS. Service Connection Installation 6. Air and Vacuum Valve Details; Blowoff Details; Cathodic Protection Details; Fire Hydrant and Fire Service Details; General Water Information Details; Miscellaneous Water Details; Pipeline Details; Backflow Prevention Details; Water Service Lateral Details; Thrust and Anchor Blocks and Pipe Restraint Details; Valve Details; Standard Drawings - Sewer. It is divided into the "upper" lateral and "lower" lateral. 2standard manhole. WASTEWATER (PRESSURE) FORCE MAIN, PROPOSED. 54 existing 12"&216; storm sewer el124. Minimum velocity of 3 fps and maximum velocity of 7 fps under all operating conditions. You see, your home&x27;s drain lines carry wastewater away from your home and are designed like a treethe. for the full depth of the structure. Steps For How to Clear A Main Sewer Line Clog. 1 IsolationAccess Valve and Manhole. A sewer cleaner uses high-pressure water to break up the blockage, scour the pipe walls and flush the debris down the sewer system to the vacuum hose. Check the following water fixtures Toilets. source vhb (steel reinforced for hs-20 loading) notes 1. CLEANOUT DETAILS SC-01Sewer Main Cleanout for 150mm (6") and 200mm (8") Mains (11-23-2011) SEWER INFORMATION SI-01Standard Symbols for Sewer Construction Drawings (11-23-2011) MANHOLE DETAILS SM-011500mm (60") Diameter Precast Manhole Installation (03-01-2001) SM-021500mm (60"). as 5 min. FORCE MAIN PIPE EMBEDMENT C-900 DIP. PIPE OR HDPE 4710. SWR09 Standard 24 Sewer Cleanout Frame and Lid SWR10 Sewer Force Main Cleanout SWR11 Standard Sewer Pipe Zone and Trench Backfill SWR12 Standard Pipe Trench Detail in Existing Streets SWR13 Concrete Crown Protection for. Pressure surge control devices. architects and engineers in the preparation of detailed plans and specifications. Sanitary Sewer Clean-Out Lid Detail 1 of 2 1142010 SS 22. Fittings for PVC sanitary sewer force mains shall be ductile iron castings. Product Details. cleanout shall be placed inside a standard cleanout box (see s-3,. 1 Polyvinyl Chloride (PVC) Pipe All pipe for sanitary sewer pressure piping (force mains) shall conform insofar as appropriate to the City of Sioux Falls Supplemental Standard Specifications for water main. 15 Force Mains. Standard Drawings Title Page (08-23-2019); Table of Contents (02-11-2020). When the lateral clogs, it can cause sewage to back up into the drains, creating both a mess and health hazard. typical force main cleanout detail. 4 Inches or Greater (JPG) SS-FM-10 Force Main Markers (JPG) SS-FM-2 In-Line Cleanout F. Temporary Cleanouts 6. Transition Manhole Force Main to Gravity Sewer S6. markers shall be labeled "raleigh sewer" 3. County Standard Sanitary Sewer Details that are applicable to the type of project. WD-09 Temporary manifold for testing & chlorination. FORCE LATERAL Shall mean that portion of a pressurized side sewer force lateral lying. 0 Cleanout Cover Assembly for 4" Cleanouts S5. ) will be reviewed by the. Lids shall have 2" raised letters marked "SEWER. d) Refer to the design section -- Part E -- of this Design Manual for detailed design guidance for low pressure sewer systems utilizing grinder pumps. FORCE MAIN NOTES 1. Box 359, Charles Town, WV 25414 Phone (304) 725-2316 Fax (304) 725-4313 Web www. Sanitary Sewer Force Main (6126-6139) A one hour ferry ride - or thirty minute fast ferry ride - from downtown Seattle, Bremerton is truly a beautiful city. This section only applies to force mains with an operating pressure below 200 pounds per square inch (psi). sealed and grouted with non-shrink materials as specified in the sanitary sewer design manual. View more information on land development within a Broward County Water and Wastewater Services jurisdiction. - - - - - - city of chattanooga and hamilton county sa nitar ystorm manhole details date of original issue december 10. 18 Excavation. Operations Division SEWER FORCE MAIN THRUST BLOCK DETAIL Adopted 01132008 Approved Revised Detail Number SEWER -17. forcemain, when capitalized, may offset or exceed the. 17 Service Lateral or Force Main Connection to a Manhole (PDF) S-1. Section 03300 - Cast-In-Place Concrete 1. Pressurized Reclaimed Water System - 3-Rod Grounding Grid Detail Vacuum Sewer - Isolation Valve & Box with Optional Gauge Tap Vacuum Sewer - Minimum Spacing between Connections Vacuum Sewer - Lift Detail and Slope Schedule Vacuum Sewer - Branch to Main Connection Assembly Vacuum Sewer - Valve Pit to Main Connection. FINISHED GRADE. sewer dwg no. sewer force main 4&x27;-6" 2&x27;-6" s-8rrh 1-21-00 dhl 6-18-08 standard main marker for sewer force mains in easements notes 1. main sewer, and shall be located within the building lot boundaries. Sewer Force Main Toning Wire Box. Sewer force mains shall conform to the material requirements for water mains. Lateral Connection 6. New Castle County Government Center 87 Read&x27;s Way New Castle, DE 19720 Phone 302-395-5555. 02 -p lnltdl issue rwision - 12 10 99. 28, 27. A minimum of one clean-out shall be installed in each sewer service lateral as shown on Drawing . Aug 26, 2016 SAN-9-3 Grinder Pump Station And Pressure Building Sewer Installation. SS-20 Force Main Wet. By contrast, clay, ABS, and PVC pipe are all subject to breakage. 3 Inches or Greater (JPG) SS-FM-3 F. 35 Sewer Service Connection to Force Main (PDF) S-1. Sewer Details ; Line Marker ; Mandrel Sizes ; New Force Main to Existing Manhole Connection ; Pavement Cleanout Detail . 07 Low-Pressure Sewer Clean-Out At End of Main;. Trench Detail (JPG) SS-FM-4 F. 7-1 Manhole Frame and Cover. blind flange with stainless steel bolts, with threaded ends flanged cross. It is critical to get the proper help to repair or replace the sewer lines as soon as possible to avoid. flanged wye 30" manhole ring and cover with adjusting rings. DISCHARGE OUTLET SHALL NEVER BE BELOW CROWN OF DOWNSTREAM PIPE. 04 METHOD OF MEASUREMENT. Sanitary Force Main Cleanout. SANITARY PRECAST MANHOLE TYPE. 7 Connection to Existing Force Main in Tunnel Access Vault A2. LP-7 In-Line CleanoutValve Pit for Low Pressure Sewer Main LP-8 Curb Stop and Box Detail LP-9 New Installation Grinder Pump Connection LP-10 In-Line Terminal Cleanout for Low Pressure Main FORCE MAIN DETAILS (FM) FM-1 Air Release Valve and Chamber FM-2 FlushingCleanout Chamber (T erminal) FM-3 Forcemain Locator Assembly. document seq 0. 3 - GRAVITY SEWER MATERIALS o No 90-degree fittings. Sanitary Sewer Service Line Clean-Out Connection. 0 ww-1. 11 14. standard storm sewer drawings (ss-prefix). Fade resistant and designed specifically for outdoor environments. 24 Service Connections to Existing Mains. Sanitary Sewer Fast Facts. sewer service main tap detail. Standard Sanitary Sewer Details - Pierce County, WA. changed sewer. skyward valpo, invidious instances

Rock Excavation in Trench, Blast - All Pipes 139 CY. . Sewer force main cleanout detail

wastewater 7 - sewer & force main common trench. . Sewer force main cleanout detail zillow pittsburg tx

DESIGN STANDARDS MANUAL FOR WATER AND WASTEWATER SYSTEMS January 30, 2013 Water Services Department. Force mains do not work via gravity. Location map. plastic marker shall be green in color. SS12 Sanitary Service Lateral Clean Out Frame and Cover For Heavy Loads SS13 Sanitary Sewer Main Line Clean Out Box SS14 Sanitary Sewer Service Connection SS15 Dual Sanitary Sewer Service Connections SS16 Deep Sanitary Sewer Service Connection SS17 Force Main Saxophone SS18 Force Main Connection To HRSD Force Main SS19 Manhole Insert. shared private main. If your home or commercial property has sewage issues, our pros can help. For sloped, circular-cross-section sewer mains, acting under the force of. Increasing Size S300-4 S309. wastewater 7 - sewer & force main common trench. Cleanouts must be installed on all sewer building connections to provide a. Drop Manholes. SWR-11 Standard Sewer Pipe Zone and. Standard Drawings Title Page (08-23-2019) Table of Contents (02-11-2020) CLEANOUT DETAILS. 33 34 00 - Sanitary Sewer Force Mains; STANDARD DETAILS. OVERVIEW A Developer or Property Owner may request that the Limerick Township Sewer Department approve a residential. Page 17. 03 Trench Box and Sheeting 100 401. Public force main means a sanitary force main pipe owned and. Low Pressure Force Main into Manhole Connection 75. S-1 Requirements for Construction near Lakefront Sewer Line. sanitary clean out s sanitary dump station pump non petroleum pump petroleumfuel pump station sanitary sewer water faucet sprinkler gauges (described) electrical outlet transformer power telephone booth gas regulator. SPL NO. WHEN JOINING TWO PIECES OF MAIN OR LATERAL, USE A NEOPRENE RUBBER SLEEVE. 12 Creek Crossing and Earth Fill Over Sewer Pipe A2. 02534-04 Service Reconnection on New or Replacement Sewer; 02534-05 Standard Cleanout Detail on. list of sewer details 1. Environment One Corporation - Environment One. as 5 min. Design and Construction Standards. 02 Grinder Pump Installation Detail (PDF) (TIFF) 072009 04. cleanout shall be placed at right-of-way or edge of easement 2. Force Main Air ReleaseVacuum Breaker Valves. All installation details are governed by the local code authority and must be approved through one or more inspections. 116 Force Main Details, Air and Vacuum Release Valve Assembly (PDF) 117 Pipe Sewer Data PVC Pipe Installation (DWG) 117 Pipe Sewer Data (PDF). All our plumbers are seasoned pros, and have been doing sewer cleanout installations for years, so give us a call at 416-749-1800 at anytime that is convenient for you, to have a sewer cleanout installed at your property. sanitary gravity sewer pipe shall be 1. The system also includes 10 District lift stations and four miles of force main. Single Family Simplex Sewer Lift Station Gravity Force-Main Connection. 6 Shallow Brick Sanitary Sewer Manhole. Existing Manhole Abandonment. Standard Details - Broward County, Florida. It is often located near a flower bed. joints with stainless steel bolts. notes 1. width, 2 clear on 2" unless grade sleeves. Drop Inlet Filter Fabric Barrier 20. 13 Ductile Iron Pipe and Fittings. 515 Discharge for Private Force Main September 2017. P-5 Low Pressure Sewer Detail, Terminal Cleanout Flushing Connection. 04 Easement Width Determination;. Revised Date SAN-1 Building Sewer Connection Layout Sept 6, 2013. The tape shall be marked with black lettering clearly identifying the pipeline as sanitary sewer. 06 Low-Pressure Sewer Individual Grinder Pump System 14. to be spaced every 300 feet on each side of any roadway or junction. Weston & Sampson worked together with Spartanburg Sanitary Sewer District to design a 42" Force Main Pig Launch at Lawson&x27;s Fork Pump Station & Retrieval at Fairforest Wastewater Treatment Plant (WWTP). detail 404-1 only. City of Phoenix Water Services Department - 2017 Design Standards Manual for Water and Wastewater Systems v Discharge The disposal of sewage, water or any other liquid or liquidsolids mixture by any sewer user into the sanitary sewer system. SM200 for bedding detail. 30 LPFM - TERMINAL FLUSHING CLEANOUT (END OF LINE) 27. sanitary sewer details. clean out is to be installed per department standards prior to water meter installation. Date Last Revised; 04. standard specification d-3033. 8 Trench Detail (Force Main & Gravity Sewer in Same Trench) A2. Main Cleanout for 150mm (6") and 200mm (8") Mains (11-23-2011) SEWER INFORMATION SI-01Standard Symbols for Sewer Construction Drawings (11-23-2011) MANHOLE DETAILS SM-011500mm (60") Diameter Precast Manhole Installation (03-01-2001) SM-021500mm (60") Diameter Shallow Precast Manhole Installation (03-01-2001) SM-031500mm (60"). Sanitary drainage piping from plumbing fixtures in buildings and sanitary drainage piping systems from premises shall be connected to a public sewer. 4010-C-1 Sanitary Sewer Force Main, Trenched, (Type), (Size) LF. PVC PIPE AND PVC FITTINGS SHALL BE SCHEDULE 80, PRESSURE. note 8" sewer main in the street 6" side sewer 6" cleanout at property line. SEWER REPAIR SERVICE IN TORONTO. Specifications Collectively the Standard Specifications and Details for sanitary sewer and water facilities and all of the written technical descriptions of materials, equipment, construction systems, standards and. Flush Cleanout & Service Line Detail A2. markers shall be labeled "raleigh sewer" 3. grawty sewer 7 &92; class -8- concrete connection of force main to manhole 0 no - -. Pipe and Fittings. SS131 Sanitary Sewer Main Line Clean Out Box SS132 Sanitary Sewer Main Line. 25 Low Pressure Sewer System Service Connection Detail. Please note November 1, 2004 is the revision date for all documents unless otherwise noted. One of the best things about cast iron pipe is that it is incredibly strong. DRIVEWAYS AND SIDEWALKS (PDF) 829 Auto blow Off Flush Station (DWG) 829 Auto blow Off Flush Station (PDF). - - - - - - city of chattanooga and hamilton county sa nitar ystorm manhole details date of original issue december 10. DRIVEWAYS AND SIDEWALKS (PDF) 829 Auto blow Off Flush Station (DWG) 829 Auto blow Off Flush Station (PDF). Tel (416) 964-9415 1-800-268-7070 Email infocarsondunlop. W-1 Precast Thrust Block. Easy online ordering for the ones who get it done along with 247 customer service, free technical support & more The purpose of the donut is to displace the weight of a vehicle or lawn mowers tire Detail Number Description Theyre often covered with a plastic box or a concrete slab for protection and a better appearance Many home sewer. All pipe for sanitary sewer pressure piping (force mains) shall. Appendix A (Gravity Sanitary Sewer System General Standard Notes) PDF Appendix B (Sanitary Sewer &x27;Force Main System&x27; General Standard Notes) PDF Appendix C (Water Distribution System General Standard Notes) PDF Typical Bird Bath Drain and Cleanout Structure Layout Plan PDF Brick Sidewalk Details PDF Conflict Boxes. S-14 MANHOLE OVER EXISTING SEWER MAIN. 0 gainesville regional. Operations Division SEWER FORCE MAIN THRUST BLOCK DETAIL Adopted 01132008 Approved Revised Detail Number SEWER -17. Standard Detail for Concrete Encasement, for a length as directed by the City Engineer. It is recommended that a clean-out or blowoff be provided at low points, but it is not mandatory. Force mains are constructed from various materials and come in a wide range of diameters. 05152020 Mandrel Sizes 03242010 New Force Main to Existing Manhole Connection 05152020 Pavement Cleanout. PVC PIPE AND PVC FITTINGS SHALL BE SCHEDULE 80, PRESSURE. SEWER MAIN BEDDING AND UNDERDRAIN DETAIL. The wastewater is sanitized first before it is eventually released. One Fernco Saddle will fit and 6 and larger sewer mains. 54 existing 12"&216; storm sewer el124. dwg date june 2018 appd. 30 lpfm - terminal flushing cleanout (end of line) 27. . 2 bill ebay